Our 300kW (375kVA) diesel generator set is a heavy-duty industrial power unit manufactured conforming to CE standards, suitable for both prime continuous power and emergency standby power supply. Available in open frame, silent soundproof canopy and mobile trailer versions. The genset can be configured with Weichai, Yuchai, Cummins and other well-known brand turbocharged diesel engines, coupled with brushless pure copper alternator. It supports customizable 50Hz/60Hz, single/three-phase voltage to meet power demands of factories, mining sites, data centers, commercial complexes and municipal engineering projects. Optional ATS automatic transfer switch enables unattended automatic startup once utility power fails.
Diesel Generator Set
Open Type 300kW Turbocharged Diesel Emergency Power Generator
-
Clear shipment tracking
-
Rigorous quality inspection
-
Has good after-sales service
Detailed Description
Product Feature
1.Wide application for factories, mining, data centers, commercial complexes, municipal engineering
2.Multiple protection: low oil pressure, high coolant temp, overload, overspeed, over/under voltage
3.Comply with ISO8528, CE, ISO9001 international standards
4.Prime Power 300kW / Standby Power 330kW, heavy-duty for continuous & emergency power supply
5.Multiple protection: low oil pressure, high coolant temp, overload, overspeed, over/under voltage
6.High-performance anti-vibration dampers, effectively suppress vibration transmission






Technical Specifications of 300kw Diesel Generator Set
| Classification | Item | Standard Specification | Optional Customization |
|---|---|---|---|
| Power Rating | Prime Power (PRP) | 300kW / 375kVA | N/A |
| Standby Power (ESP) | 330kW / 412.5kVA | N/A | |
| Power Factor | 0.8 Lagging (Three Phase) | 0.9 customizable | |
| Frequency | 50Hz | 60Hz (North America) | |
| Rated Speed | 1500rpm @50Hz | 1800rpm @60Hz | |
| Phase System | Three Phase 4-Wire | Single Phase optional | |
| Voltage Specification | Standard Output Voltage | 400V/230V | 208V, 415V, 480V, 600V |
| Voltage Regulation Mode | AVR Automatic Regulation | Digital AVR upgrade | |
| Static Voltage Deviation | ≤ ±1.0% | High-precision ≤ ±0.5% | |
| Waveform Distortion THD | ≤ 3% (No-load) | ≤ 1.5% low distortion version | |
| Diesel Engine Data | Engine Brand | Weichai / Yuchai Default | Cummins / Perkins / Doosan |
| Cylinder Configuration | Inline 6-Cylinder | N/A | |
| Air Intake Mode | Turbocharged & Intercooled | Natural intake unavailable | |
| Cooling System | Closed Circuit Water Cooling | Heavy-duty radiator for high ambient | |
| Combustion System | Direct Injection Mechanical Pump | Electronic ECU injection | |
| Starting System | 24V DC Electric Start | Dual battery cold start upgrade | |
| Filter System | Air / Fuel / Oil Triple Filter | Heavy-duty desert air filter | |
| Emission Standard | EU Stage II | EPA Tier 2 / Tier 3 | |
| Alternator Data | Alternator Type | Brushless, Self-excited | N/A |
| Winding Material | 100% Pure Copper | Aluminum winding for cost version | |
| Insulation Class | H Class | N/A | |
| Protection Grade | IP23 | IP54 dustproof & waterproof | |
| Efficiency (Full Load) | ≥ 95.2% | High-efficiency ≥96.0% | |
| Bearing Structure | Single bearing | Dual bearing heavy duty | |
| Fuel Consumption Data | No-load Fuel Consumption | 18.5 L/h | N/A |
| 50% Load Consumption | 42.8 L/h | N/A | |
| 75% Load Consumption | 58.6 L/h | N/A | |
| 100% Full Load Consumption | 76.2 L/h | N/A | |
| Base Fuel Tank Capacity | 450L | 1000L extended tank | |
| Noise & Vibration | Open Type Noise @7m | ≤ 78dB(A) | N/A |
| Silent Type Noise @7m | ≤ 68dB(A) | Ultra-silent ≤62dB(A) | |
| Vibration Reduction | High-density rubber dampers | Spring vibration isolator | |
| Exhaust Silencer Grade | Industrial standard silencer | Residential grade ultra silencer | |
| Control & Protection | Standard Controller | SmartGen HGM6120 | Deepsea DSE7320 / DSE8610 |
| Monitoring Parameters | Voltage, Current, Frequency, Oil Pressure, Coolant Temp, Runtime | Power, Energy, Harmonic data | |
| Protective Functions | Low oil pressure, high temp, overload, overspeed, under/over voltage | Earth fault, reverse power protection | |
| ATS Interface | Reserved | Integrated ATS 160A/250A/400A | |
| Remote Monitoring | Not included | 4G/GPRS cloud remote control | |
| Dimension & Weight | Open Type Dimension (L×W×H) | 2850×1150×1680 mm | Custom frame size |
| Silent Type Dimension | 3250×1350×2100 mm | Compact optimized canopy | |
| Open Type Net Weight | 2850 KG | N/A | |
| Silent Type Net Weight | 3680 KG | N/A | |
| Ambient & Durability | Working Altitude | ≤1000m (no power derating) | High altitude version ≤3000m |
| Ambient Temperature Range | -20℃ ~ +45℃ | Cold resistant -40℃ / Tropical +55℃ | |
| Design Service Life | ≥25 Years | N/A | |
| Certification | Compliance Standard | CE | EPA, CSA, SONCAP optional |
Why Choose Yiyue
1.Factory direct supply without middlemen, cost-effective price and reliable quality warranty
2.Professional technical team offers load calculation, scheme selection, drawing confirmation and technical consultation
3.Full customized service: frequency, voltage, silent canopy, trailer, container, ATS, remote monitoring, OEM logo & color
4.Stable production lead time, support bulk distributor orders and large EPC infrastructure projects
Packaging And Transportation
Yiyue Electric implements standardized packaging and shipping management to protect transformers, switchgears, cables and electrical components throughout the entire delivery process, ensuring products arrive in intact condition.
Customized Packaging Solutions
- Small-sized products: Moisture-proof bubble wrap + reinforced cartons with anti-collision corner protectors
- Medium & large equipment: Stretch film sealing for full moisture resistance, with foam padding on vulnerable parts for shock absorption
- Heavy machinery & export shipments: ISPM15-compliant fumigated wooden cases secured with steel belts, suitable for long-distance international transit
All packages are marked with clear shipping marks and handling warnings for standard operation.
Production Lead Time
- Standard in-stock items: 5–7 working days upon payment confirmation
- Customized non-standard products: 7–15 working days after design confirmation & deposit
- Large orders with special requirements: Lead time subject to separate confirmation
Shipping Method Region Estimated Transit Time Remarks Sea Freight Southeast Asia 15–25 working days Port to port, FCL & LCL available Middle East 15–25 working days Port to port, FCL & LCL available North America 20–30 working days Port to port, FCL & LCL available Europe 25–35 working days Port to port, FCL & LCL available Oceania 20–30 working days Port to port, FCL & LCL available Africa 30–45 working days Port to port, FCL & LCL available Air Freight Southeast Asia 5–7 working days Airport to airport, for urgent orders Middle East 5–7 working days Airport to airport, for urgent orders North America 10–15 working days Airport to airport, for urgent orders Europe 7–15 working days Airport to airport, for urgent orders Africa 4–6 working days Airport to airport, for urgent orders Air Freight (Express) Worldwide Major Countries 3–7 working days Door-to-door, suitable for small spare parts
Yiyue Electric implements standardized packaging and shipping management to protect transformers, switchgears, cables and electrical components throughout the entire delivery process, ensuring products arrive in intact condition.
Customized Packaging Solutions
- Small-sized products: Moisture-proof bubble wrap + reinforced cartons with anti-collision corner protectors
- Medium & large equipment: Stretch film sealing for full moisture resistance, with foam padding on vulnerable parts for shock absorption
- Heavy machinery & export shipments: ISPM15-compliant fumigated wooden cases secured with steel belts, suitable for long-distance international transit
All packages are marked with clear shipping marks and handling warnings for standard operation.
Production Lead Time
- Standard in-stock items: 5–7 working days upon payment confirmation
- Customized non-standard products: 7–15 working days after design confirmation & deposit
- Large orders with special requirements: Lead time subject to separate confirmation
| Shipping Method | Region | Estimated Transit Time | Remarks |
| Sea Freight | Southeast Asia | 15–25 working days | Port to port, FCL & LCL available |
| Middle East | 15–25 working days | Port to port, FCL & LCL available | |
| North America | 20–30 working days | Port to port, FCL & LCL available | |
| Europe | 25–35 working days | Port to port, FCL & LCL available | |
| Oceania | 20–30 working days | Port to port, FCL & LCL available | |
| Africa | 30–45 working days | Port to port, FCL & LCL available | |
| Air Freight | Southeast Asia | 5–7 working days | Airport to airport, for urgent orders |
| Middle East | 5–7 working days | Airport to airport, for urgent orders | |
| North America | 10–15 working days | Airport to airport, for urgent orders | |
| Europe | 7–15 working days | Airport to airport, for urgent orders | |
| Africa | 4–6 working days | Airport to airport, for urgent orders | |
| Air Freight (Express) | Worldwide Major Countries | 3–7 working days | Door-to-door, suitable for small spare parts |