    Support OEM & ODM Customization

    Our 10kVA Rackmount Online UPS adopts advanced high-frequency true online double conversion topology. AC power is continuously converted to DC then inverted back to stable AC power, achieving 0ms switching time between mains and battery mode. No power interruption occurs during grid outage, which is critical for servers, switches and precision network devices.
    This 10000VA rack mount UPS is designed for standard 19-inch server cabinets, saving valuable space in server rooms, communication closets and monitoring centers. Equipped with an intelligent LCD panel, operators can check real-time input/output voltage, load rate, battery status, working mode and fault alarms conveniently.
    Different from standard built-in battery UPS, this unit reserves external battery terminals, allowing customers to configure independent battery banks to customize backup time from several minutes to multiple hours according to project requirements.
    Built-in comprehensive multi-level protection mechanisms effectively defend equipment against overload, overvoltage, undervoltage, short circuit and overheating. Intelligent variable-speed fan adjusts rotation speed based on load and temperature, lowering noise and reducing energy consumption.
    Suitable for commercial, industrial and IT infrastructure scenarios, widely deployed in small data centers, office server rooms, security monitoring systems and communication equipment.
    .

     

    • Clear shipment tracking

    • Rigorous quality inspection

    • Has good after-sales service

    Share:

    Detailed Description

    Product Feature

    ✅ True Online Double Conversion, 0ms Transfer Time

    ✅ Pure Sine Wave Output, compatible with all sensitive IT loads

    ✅ 19-inch Standard Rackmount Design, Easy Installation in Network Cabinet

    ✅ Large LCD Display with complete operation data & fault warning

    ✅ Support External Battery Pack, Customizable Long Backup Runtime

    ✅ Wide Input Voltage Range, Strong Adaptability to Unstable Grid

    ✅ Full Protection: Overload, Overvoltage, Undervoltage, Short Circuit, Overheat, Overcharge & Deep Discharge Protection

    Technical Specifications of 10kVA Rackmount Online UPS

    ItemParameter
    Model10kVA Rackmount Online UPS
    Rated Capacity10000VA / 9000W (PF=0.9)
    TopologyTrue Online Double Conversion, High Frequency
    Output WaveformPure Sine Wave
    Installation19” Standard Rackmount, 3U Height
    Input
    Rated Input Voltage220/230VAC Single Phase
    Input Voltage Range160~275VAC
    Input Frequency45 ~ 65Hz, Auto Detect
    Power Factor≥0.95
    Output
    Rated Output Voltage220/230VAC
    Output Frequency50/60Hz Auto Synchronization
    Voltage Regulation±1% (Battery Mode)
    Transfer Time0ms (Mains ↔ Battery)
    Overload Capacity105~125%: 10min; 125~150%: 30s; >150%: Instant shutdown
    Battery Section
    Battery TypeExternal Lead-acid Battery (Not Included)
    DC VoltageDC 192V
    Charging ModeIntelligent Constant Voltage Float Charge
    Control & Display
    DisplayLCD Digital Display + LED Indicator
    Communication PortOptional USB / RS232 / SNMP Slot
    Cooling SystemIntelligent Speed Adjustable Fan
    Operation ModeNormal Mode / Battery Mode / ECO Mode
    Protection FunctionsOverload, Overvoltage, Undervoltage, Short Circuit, Overheat, Overcharge, Deep Discharge Protection
    Environment
    Operating Temperature0℃ ~ 40℃
    Storage Temperature-20℃ ~ 55℃
    Humidity20% ~ 90% Non-Condensing
    Working Altitude≤1500m (Derate power above 1500m)
    Noise Level≤55dB @ 1 Meter
    Dimension (W×D×H)Custom (Fill actual cabinet size mm)
    Net WeightCustom (Fill actual weight kgs)
    Compliance StandardCE

    Why Choose Yiyue

    All electrical products pass strict factory tests in line with IEC, CE and ANSI standards, with outstanding anti-corrosion and sealing performance for outdoor application.

    Hefei Yiyue Electrical Equipment Trading Co., Ltd focuses deeply on the core sectors of the electrical equipment industry.

    Based in Hefei, the company serves the domestic market while expanding its reach nationwide and globally.

    Driven by the mission to “connect the world’s advanced electrical technologies and build an intelligent, efficient energy ecosystem”.

    It strives to become a top-tier domestic and internationally renowned provider of electrical equipment trading and comprehensive services.

    The company owns an independent industrial park covering 8,000 square meters.

    Main products: generator sets, transformers, box-type substations, high and low voltage switchgear, power distribution cabinets, gas-insulated ring main units (RMUs), vacuum circuit breakers, power system accessories, power cables.

    Compact 19-inch rack chassis, easy maintenance and cabinet deployment Flexible battery configuration to meet different project runtime demands

    Packaging And Transportation

    Yiyue Electric implements standardized packaging and shipping management to protect transformers, switchgears, cables and electrical components throughout the entire delivery process, ensuring products arrive in intact condition.

    Customized Packaging Solutions

    • Small-sized products: Moisture-proof bubble wrap + reinforced cartons with anti-collision corner protectors
    • Medium & large equipment: Stretch film sealing for full moisture resistance, with foam padding on vulnerable parts for shock absorption
    • Heavy machinery & export shipments: ISPM15-compliant fumigated wooden cases secured with steel belts, suitable for long-distance international transit

    All packages are marked with clear shipping marks and handling warnings for standard operation.

    Production Lead Time

    • Standard in-stock items: 5–7 working days upon payment confirmation
    • Customized non-standard products: 7–15 working days after design confirmation & deposit
    • Large orders with special requirements: Lead time subject to separate confirmation
    Shipping MethodRegionEstimated Transit TimeRemarks
    Sea FreightSoutheast Asia15–25 working daysPort to port, FCL & LCL available
    Middle East15–25 working daysPort to port, FCL & LCL available
    North America20–30 working daysPort to port, FCL & LCL available
    Europe25–35 working daysPort to port, FCL & LCL available
    Oceania20–30 working daysPort to port, FCL & LCL available
    Africa30–45 working daysPort to port, FCL & LCL available
    Air FreightSoutheast Asia5–7 working daysAirport to airport, for urgent orders
    Middle East5–7 working daysAirport to airport, for urgent orders
    North America10–15 working daysAirport to airport, for urgent orders
    Europe7–15 working daysAirport to airport, for urgent orders
    Africa4–6 working daysAirport to airport, for urgent orders
    Air Freight (Express)Worldwide Major Countries3–7 working daysDoor-to-door, suitable for small spare parts
    Applications
    FAQs
    WhatsApp

    Leave a message!

    Leave a message!